slab-sim

The system, part by part

A whole-house layout of the weather-compensated system controlling three rooms with different comfort targets — a cool bedroom, a warm living room, a warmer bathroom. It shows every physical part and, importantly, the two layers of control that let one boiler serve many rooms well.

← How it worksOpen the demo →
supply ≈ 36 °Creturn ≈ 27 °COUTDOOR SENSORtemp + trend (anticipatory)−4 °C ↓ fallingWEATHER-COMPENSATION CONTROLLERreads outdoor weather + every room sensor→ sets one supply temperature + each zone valvesets supply Tzone valve commandssensor bus — all rooms reportGAS BOILER24 kW · non-cond.(condensing option)BUFFERTANKdamps cyclingPcirculator(runs 24/7)3-WAY MIXVALVEblends hot+returnsupply railreturn railMANIFOLDDormitorio · BedroomZVradiant slab loopTHERMOSTAT18.2 → 18 °Csetpoint 18 °C · own zone valveLiving · ComedorZVradiant slab loopTHERMOSTAT20.9 → 21 °Csetpoint 21 °C · own zone valveBaño · BathroomZVradiant slab loopTHERMOSTAT22.1 → 22 °Csetpoint 22 °C · own zone valvewarm supply watercool return watercontrol / sensor signal

The water side — one temperature for the whole house

Follow the amber path. The gas boiler heats water; a buffer tank gives it a healthy volume to heat so a non-modulating boiler isn't forced to short-cycle. The circulator pump runs continuously — this system never switches the heat fully on and off. The key part is the 3-way mixing valve: it blends hot boiler water with cool return water to produce a single supply temperature — just warm enough that the floor gives off exactly the heat the house is losing right now. On a −4 °C evening that might be ~36 °C water; on a mild afternoon, ~26 °C. That is "weather compensation", and it is set by the controller from the outdoor sensor, not by any single room.

Serving many rooms — the manifold and zone valves

The supply water reaches the manifold, a pair of rails (supply and return) with one zone valve (ZV) per room. Each room's radiant slab loop taps off the supply rail through its zone valve, winds through that room's floor, and returns to the return rail. All rooms share the same supply temperature — the manifold is simply how one heat source is split among them.

Each room has its own thermostat reporting to the controller, and its own zone valve. In the diagram the bedroom targets 18 °C, the living room 21 °C, the bathroom 22 °C — different comfort levels from one boiler.

Two layers of control (this is the important part)

A single supply temperature can't be perfect for three rooms with three different targets and different sun, draughts and occupancy. So the system controls on two timescales:

  1. House layer — the mixing valve (slow, weather-driven). Sets the one supply temperature so it covers the whole house's heat loss. This does the heavy lifting and keeps every slab near equilibrium, so no room swings wildly.
  2. Room layer — the zone valves (per-room trim). Each room opens or closes its valve to fine-tune its share. A sunny living room that's drifting warm closes its valve for a while; a cold bathroom keeps its valve open longer. Because the water is already at the right low temperature, these adjustments are gentle nudges — not the violent full-on/full-off swings of a conventional thermostat driving 45 °C water.

The house layer removes ~90 % of the disturbance (the weather); the room layer mops up what's local to each room. That division is exactly why weather compensation scales cleanly from one room to a whole house.

Parts list

PartCountJob
Gas boiler1Makes hot water. Condensing gains efficiency at the low return temps this system runs.
Buffer tank1Adds water volume so the boiler burns in long cycles, not short bursts.
Circulator pump1Moves water continuously through the loops.
3-way mixing valve1Blends to the weather-compensated supply temperature — the core control actuator.
Outdoor sensor1Feeds the controller outdoor temperature + its trend (anticipation).
Manifold1Splits supply/return among the room loops; hosts the zone valves.
Zone valve1 per roomOpens/closes that room's floor loop for per-room trim.
Room thermostat1 per roomReports each room's temperature + setpoint to the controller.
Controller1Reads all sensors; sets the supply temperature and every zone valve.

How this relates to the simulator

The demo and lab currently model the house layer in detail — one thermal zone, the mixing valve, boiler and slab — because that is where the big comfort and gas differences live. The room layer (per-room zone valves) is the natural next step for modelling a real multi-room house, and it's where a per-room predictive controller — like the one explored as the third controller in the lab — fits: weather compensation sets the water temperature for the house, and a smart zone valve trims each room locally. The two approaches are layers of the same system, not rivals.

Schematic is conceptual — pipe routing is simplified for clarity (crossings without a junction are not connections). Temperatures shown are illustrative of a cold evening.

→ See it run: the side-by-side demo