Conventional thermostat vs weather-compensated control

Same house, same week of Bariloche weather, same gas boiler. One is controlled by a conventional on/off room thermostat; the other by continuous circulation with a weather-compensated supply temperature. Watch the indoor temperature. New here? How it works →

Big diurnal swing, heavy solar gain. The hardest case — it most exposes the on/off controller's overshoot.

Conventional — gas
0.0 kWh
Weather-comp — gas
0.0 kWh
Difference
+0.0 %

Indoor air temperature

comfort band shaded (setpoint ± 0.5 °C)

Supply water temperature

weather-comp continuous; conventional = 45 °C only while its pump runs
d0 00:00

Conventional on/off

…

Weather-compensated

…

This is a calibrated physical model, not a measurement. It uses an RC thermal model of a 120 m² slab house and a non-condensing gas boiler with real modulation, cycling and mixing-valve limits. Both systems are modelled with the same hardware, including a 200 L buffer tank on the boiler primary (standard practice for a non-modulating boiler on a low-temperature floor). Where the weather-compensated system shows slightly higher gas, that is the cost of actually holding the house at temperature overnight — the conventional thermostat "saves" gas by letting it fall to 17 °C and recovering cold mornings. Actual results depend on your building's insulation, slab, glazing and boiler. The intent is to show the control paradigm difference — an on/off thermostat cannot settle a high-mass slab — not to promise a specific number for a specific house.